NVIDIA A100 40GB / 80GB
40GB and 80GB versions, each in PCIe or SXM4 form. Diagnosis and board-level repair.
A100 repairOUR SERVICES
The reported symptom starts the investigation. Board condition, electrical measurements and platform testing determine whether the next step is circuit repair, component rework or a replacement assessment.
SUPPORTED HARDWARE
40GB and 80GB versions, each in PCIe or SXM4 form. Diagnosis and board-level repair.
A100 repairPCIe and SXM5 versions. Assessment of power delivery, device recognition and interconnect behavior.
H100 repairPower, cooling and HBM3e-related fault assessment in a compatible host environment.
H200 repairGeForce RTX 30/40, RTX A-series, A10/A30/A40 and L40/L40S. View the supported model list.
PCIe card repairPCIe MODELS
Consumer PCIe graphics cards.
Consumer PCIe graphics cards.
Professional workstation PCIe cards.
Server and data center GPU cards.
Repair service is available for the listed models, subject to inspection and parts availability. Confirm the manufacturer, exact model, memory capacity and part number at intake. Ti, SUPER and other board variants require a separate compatibility review.
CAPACITY & FORM FACTOR
| GPU variant | Memory | Form factor | Assessment requirements |
|---|---|---|---|
| A100 40GB PCIe | 40GB HBM2 | PCIe card | PCIe host and cooling matched to the exact board. |
| A100 80GB PCIe | 80GB HBM2e | PCIe card | 80GB-specific assembly and compatible test configuration. |
| A100 40GB SXM4 | 40GB HBM2 | SXM4 module | Compatible SXM4 carrier, power and cooling arrangement. |
| A100 80GB SXM4 | 80GB HBM2e | SXM4 module | 80GB SXM4 assembly, carrier and package compatibility review. |
| H100 80GB PCIe | 80GB HBM2e | PCIe card | PCIe assembly, host power and system cooling. |
| H100 80GB SXM5 | 80GB HBM3 | SXM5 module | Compatible SXM5 carrier, power and cooling arrangement. |
40GB and 80GB are separate A100 configurations. The H100 repair variants listed here are 80GB. Capacity, package and board form factor must all match the assessment and replacement parts.
REPAIR CAPABILITIES
Locate failed power stages, controllers or supporting components. Repair the confirmed circuit fault and verify stable power before functional testing.
Power-fault diagnosisEvaluate solder connections and component condition before reballing or replacement. GPU and HBM work depends on package construction and fault location.
Rework and validationAssess damaged edge contacts, pads and accessible traces. Deep substrate damage may require a compatible replacement PCB and component-transfer assessment.
PCB repair routesInvestigate repeatable memory errors, driver timeouts and failures under load. Correlate logs with hardware tests before choosing a repair.
Memory-fault diagnosisAssess the GPU alongside its slot or carrier and software environment. Review PCIe or NVLink behavior only on a configuration that supports the required test.
Link-fault diagnosisWe use NVIDIA-developed diagnostic software on supported GPU and platform configurations, alongside targeted stress testing, to identify faults and verify stability after repair. Cooling, temperature and power behavior are reviewed during testing.
Post-repair checksSCOPE & FEASIBILITY
A serviceable board with a localized, accessible fault may be suitable for component replacement, trace repair or controlled rework.
Damaged PCB structure or a failed package requires a review of compatibility, part availability, remaining component condition and cost.
If the proposed work is not viable or not approved, we document the findings and agree on return arrangements with you.
Physical silicon damage and internal HBM-stack faults are outside ordinary solder-joint repair. We confirm feasibility for the actual assembly before quoting that work.
This website provides information about Tokdraw LLC repair services. Submitting an inquiry does not authorize work or guarantee that a device is repairable.
The actual diagnostic fee, repair price, parts, shipping, taxes, and service timing must be confirmed in an individual written quote. Repair work requires customer approval.
Wait for intake confirmation and shipping instructions before sending equipment. Back up accessible data and remove credentials. Component replacement is subject to compatibility, board condition, and parts availability.
Payment, warranty coverage, return shipping, unrepairable devices, and any enterprise SLA or NDA must be addressed in the accepted service agreement. Brand names identify supported hardware and do not imply manufacturer affiliation or authorization.
The repair form asks for your name, company name, email, device model, and a description of the issue so that your service request can be reviewed and answered.
When you submit, your name, company, email address, device details, and issue description are sent through Cloudflare Workers and Email Service to the Tokdraw contact inbox hosted by Gmail. We use these details to review and respond to your inquiry. Cloudflare Turnstile processes connection and browser information to prevent automated abuse. Form entries are not saved in browser storage. A downloaded copy stays on your device. Contact benjamintu@tokdraw.com with questions about your information.
The website host and Cloudflare Turnstile may receive ordinary connection information, such as your IP address and browser details. This page does not add analytics, advertising cookies, or browser-based form storage.
Do not include passwords, access tokens, payment card details, or confidential customer data. Confidential enterprise information should be exchanged through an agreed channel after any required NDA is in place.